  si o y2c v2 current sensors 1 v2 . 0 0 may 1 , 20 12 i pn = 50?600a ,v out = 4v f eat u r es ? hall effect measuring principle ? galvanic isolation betwee n primary and secondary circuit ? compact design for pcb mounting ? low power consumption ? extended measuring range (3*i pn ) ? insulated plastic case recognized according t o ul 94 - v0 advantages ? easy installation ? excellent accuracy ? no insertion losses ? excellent performance and price ? only one design for wide current ratings range ? high immunity to external interference industrial applications ? static converters for dc motor drives ? switched mode power supplies(smps) ? ac variable speed drives ? uninterruptible power supplies(ups) ? battery supplied applications ? power supplies for welding application types of products type primary nominal current r. m. s i pn (a) primary current measuri ng range i p (a) sio y2c5 0 v2 50 150 sio y2c75 v2 75 225 sio y2c1 00 v2 100 300 sio y2c150 v2 150 450 sio y2c2 00 v2 200 600 sio y2c300 v2 300 900 sio y2c400 v2 400 900 sio y2c500 v2 500 900 sio y2c6 00 v2 600 900 general descri ption for the electroni c measurement of currents: dc, ac, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit)
si o y2c v2 current sensors 2 v2 . 0 0 may 1 , 20 12 paramet ers table parameters symbol unit value conditions electrical data supply voltage(5 %) (1) v c v 15 current consumption i c ma 15 output voltage v out m v 4v40 @ i pn , r l = 10 k , t a = 25c overload capability(1ms) i pc a t 50* i pn @ i pn , r l = 10 k , t a = 25c isolation resistance r is m >1000 @ 500 vdc output internal resistance r out 100 approx load resistance (2) r l k >10 r. m. s voltage for ac isolation test v d kv 3 @5 0hz, 1 min r. m. s rated voltage safe separation v b v 500 accuracy - dynamic performance data linearity (3) (0?i pn ) l % of i pn < 1 accuracy x % < 1 @ i pn , t a = 25c ( without offset) electrical offset voltage v oe m v < 20 @t a = 25c hysteresis offset voltage v oh m v < 20 @ ip= 0; after an excursion of 1* i pn temperature coefficient of v oe tcv oe mv/k < 2 @ sio y2c50 - 75 v2 < 1 @ sio y2c100 - 600 v2 temperature coefficient of v out tcv out %/k <0.1 @% of reading response time t r s < 3 @ 90% of i pn step d i / d t accurately followed d i /d t a/ s >50 frequency bandwidth (4) bw khz dc~ 50 @ - 3db general data ambient operating temperature t a c - 40 ~ +85 ambient storage temperature t s c - 40 ~ + 105 mass m g approx 60 notes: 1) operating at 12v vc<15v will red uce the measuring range. 2) if the customer uses 1 k of the load resistor, the primary current has to be limited as the nominal. to measure the full defined measuring range, the load resistor should be at minimum 10 k. 3) linearity data exclude the electrical o ffset. 4) please refer to derating curves in the technical file to avoid excessive core heating at high frequency.
si o y2c v2 current sensors 3 v2 . 0 0 may 1 , 20 12 dimensions sioy2cv2 ( in mm. 1 mm = 0.0394 inch ) instructions of use 1) when the test current passes through the sensors you can get the size of the output voltage. (warning: wrong connection may lead to sensors damage) 2) based on user needs, the sensors output range can be appropriately regulated. 3) according to user needs, different rated input currents and output voltages of the sensors can be custo mized.
si o y2c v2 current sensors 4 v2 . 0 0 may 1 , 20 12 restrictions on product use the information contained herein is subject to change without notice. sec electronics inc. ( for short sec ) exerts the greatest possible effort to ensure high quality and reliability. nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. it is the responsibility of the buyer, when utilizing sec products, to comply with the standards of safety in making a safe design for the entire system, including redundancy, fire - prevention measures, and malfunction prevention, to prevent any accidents, fires, or community damage that may ensue. in developing your designs, please ensure that sec products are used within specified operating ranges as set forth in the most recent sec products specifications. the sec products listed in this document are intended for usage in general electronics applications (comp uter, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). these sec products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury (?unintended usage?). unintended usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, com bustion control instruments, medical instruments, all types of safety devices, etc.. unintended usage of sec products listed in this document shall be made at the customer?s own risk.


▲Up To Search▲   

 
Price & Availability of SIOY2C600V2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X