Part Number Hot Search : 
MSK621 25ETTT MC74HC KDV154 1N4937 SI975005 AHA3580 TS3022I
Product Description
Full Text Search
 

To Download IFC125 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  specification 125 watts ? small size  3.0 x 5.0 x 1.25 ? triple and quad outputs ? active pfc  meets en6100032, 3 ? overvoltage & overcurrent protection ? power good signal ? 25 c to +50 c full power ? 3 year warranty IFC125 series input input voltage ? 90-264 vac input frequency ? 47-63 hz input current ? 0.8 a max at 240 vac 1.8 a max at 100 vac inrush current ? 33 a max at 115 vac 66 a max at 230 vac power factor ? 0.98 typical earth leakage current ? 0.5 ma max at 132 vac/60hz 0.825 ma max at 264 vac/50hz input protection ? internal 2.6 a fuse output output voltage ? see table output voltage trim ? not user-adjustable initial set accuracy ? 5% maximum minimum load ? 5 w minimum load on v1 or v2 required to maintain regulation start up delay ? 1.5 s at 90 vac start up rise time ? 0.2-20 ms hold up time ? >28 ms min at full load line regulation ? see table load regulation ? see table over/undershoot ? 10% maximum transient response ? 5% max. deviation, recovery to within 1% in 500 s for a 25% load change ripple & noise ? 1% pk-pk maximum or 5 vout 50 mv maximum overvoltage protection ? v1 & v2: 113-148%, auto recovery overtemperature ? unit shuts down, recycle input to reset protection overload protection ? all outputs: 115-135%, auto recovery short circuit protection ? trip and restart (hiccup mode) temperature ? 0.04% / ?c maximum coefficient remote sense ? v1 only compensates for 0.5 v drop (not available on IFC125-31) xppower.com general efficiency ? 83% typical isolation ? 3000 vac input to output 1500 vac input to ground 500 vac output to ground power density ? 6.66 w/in 3 signals ? power good - on = logic high mtbf ? >220 khrs per bellcore environmental operating temperature ? -25 ?c to +70 ?c, derate linearly from 100% at +50 ?c to 50% at +70 ?c cooling ? 5 cfm airflow required for 125 w operating humidity ? 5-95% rh, non-condensing storage temperature ? -40 ?c to +85 ?c operating altitude ? 3000 m shock ? 15 g pk operating vibration ? 2.4 g, 5 hz to 500 hz, 3 axis emc & safety emissions ? en55022/cispr22 and fcc, class b conducted harmonic currents ? en61000-3-2 voltage flicker ? en61000-3-3 radiated immunity ? en61000-4-3, level 3 perf criteria b eft/burst ? en61000-4-4, level 3 perf criteria b surge ? en61000-4-5, level 3 perf criteria b conducted immunity ? en61000-4-6 dips & interruptions ? en61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, criteria a, b, b safety approvals ? en60950, ul 60950, csa950 per cul, ce mark lvd acdc
IFC125 15-jan-10 models and ratings acdc conn pin connector pin-outs IFC125-31 IFC125-42-3 j1 1 neutral neutral 2 3 line line j2 1 -12 vdc -12 vdc 2 +12 vdc +12 vdc 3 not used +3.3 vdc 4 not used +3.3 vdc 5 not used +3.3 vdc 6 dc gnd dc gnd 7 dc gnd dc gnd 8 dc gnd dc gnd 9 dc gnd dc gnd 10 dc gnd dc gnd 11 +5 vdc +5 vdc 12 +5 vdc +5 vdc 13 +5 vdc +5 vdc 14 +5 vdc +5 vdc j3 1 0 v sense 0 v sense 2 not used +3.3 v sense 3 power good power good output 1 output 2 output 3 output 4 model number vnom imax reg (1) vnom imax reg (1) vnom imax reg (1) vnom imax reg (1) 5.0 v 16.5 a 4% 12.0 v 5.0 a 5% -12.0 v 0.5 a 5% IFC125-31 3.3 v 10.0 a 2% 5.0 v 15.0 a 4% 12.0 v 5.0 a 5% -12.0 v 0.5 a 5% IFC125-42-3 notes 1. total regulation includes tolerance, line regulation and load regulation. 2. maximum output power not to exceed 125w with 5 cfm forced air or 70w with convection cooling. 3. for IFC125-42-3, a maximum of 80w combined +3.3v and +5v outputs with 5cfm of forced air cooling or 40w with convection cooling. mechanical details notes 1. all dimensions in inches (mm). 2. weight 0.68 lb (310 g) approx (-14 models 0.6 lb, 270g). molex mating connectors j1 housing 09-50-8031 pins 08-52-0113 j2 housing 09-50-8141 pins 08-52-0113 j3 housing 22-01-3037 pins 08-50-0123 screws shown for reference only lock washer 5.00 (127.0) 3.00 (76.2) 3.00 (76.2) 4.55 (115.6) 2.55 (64.8) ? 0.16 (4.1) (4 places) safety ground connection point pin #1 pin #1 pin #1 fastener clearance area (4 places) 1.00 (25.4) 1.25 (31.8) 0.06 (1.5) 0.19 (4.8) j1 - input connector j3 - remote sense/ pg connector pcb j2 - dc output connector for IFC125-31, -40-1, 42-3. (see pin-out table) 0.23 (5.7)


▲Up To Search▲   

 
Price & Availability of IFC125

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X