  www.schurter.com 126 power entry modules / ger?testecker-kombielemente 5145 power entry module type 5145 ?panel mount: screw-on version, front-side appliance inlet, circuit breaker type ta 45 and line filter characteristics circuit breaker with line switch, 2-pole, non-illuminated or illuminated combined with thermal overload protection optional with undervoltage- or remote trip release all single elements wired unwired versions available on request t echnical data rated voltage 125/250 vac; 50/60 hz rated currents i n 1 ) filter 1?0 a; @t a 40 ?; sev, vde, semko 1?5 a; @t a 40 ?; ul, csa ta 45 0,1?0 a; vde, see table 1 0,1?5 a; ul/csa, see table 1 leackage current, standard < 0,5 ma (250 v/60 hz) medical < 5 ? (250 v/60 hz) t est voltage (2 sec) 1,7 kvdc between l-n 2,7 kvdc between l/n-pe allowable ambient air temperatures t a ?0 ? to +55 ? climatic category 10/055/21 acc. to iec/en 60068-1 degree of protection (front-side) ip 40 acc. to iec 60529 protection class suitable for equipment with prot. cl. i, acc. to iec 61140 t erminals quick-connect 6,3 x 0,8 mm panel thickness s max. 8 mm materials: housing thermoplastic, black, ul94 v? appliance-inlet acc. to. iec/en 60320-1/c14, protection class i, pin-temperature 70 ? (cold condition) circuit breaker acc. to iec/en 60934, ul 1077, type ta45 csa 22.2 no. 235. 2-pole rocker switch, illuminated or non-illuminated. optional with undervoltage- or remote trip release short circuit capacity icn: at in < 3 a / 240 vac: 10 x in at in 3 a / 240 vac: 300 a line filter, standard and medical acc. to. iec 60939, en 133 200, ul 1283, csa c 22.2 no. 8 t echnical details see page 202 50 75 100 1) application note the rated current of the line filter must be equal or higher than the rated current of the circuit-breaker. standard or medical filter
www.schurter.com 127 power entry modules / ger?testecker-kombielemente 5145 10?000 60 2?000 1?000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 [ x i n ] 10 8 5 4 3 2 1,32 ty pe / typ t a45 rated current / nennstrom i  3 a ....  15 a 1 pole protected 2pol e protected ambient temp. umgebungstemp. +23 c multiple of rated current t ripping time n 10?000 60 2000 1000 500 200 100 50 20 10 5 2 1 0,5 0,3 0,2 0,1 [ sec ] [ min ] 10 5 1 30 20 1,05 multiple of rated current / nennstrom-vielfaches [ x i n ] 10 8 5 4 3 2 1,32 tripping time t ype / typ t a45 rated current / nennstrom i n < 3 a 1 pole protected 2po le protected ambient temp. umgebungstemp. +23 c t echnical data (continued) circuit breaker t ripping characteristics i n < 3 a t ripping characteristics i n  3  15 a effect of ambient temperature 1) the unit is calibrated for an ambient temperature of +23 ?c. to determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. ambient temperature / correction umgebungs- factor temperatur [?c] e10 0,89 e5 0,91 00,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16 dimensions panel cut-out 36 91,5 80 29 r3 m3 / ? 3,6 72 80 0 +0,2 +0,1 0 0 -0,5 0,1 43 50,7 detail a 6,3 x 0,8 mm 13,5 67,5* 6,3 x 0,8 mm mounting screw torque 0,5 nm * v ersion ta45 with undervoltage release diagrams standard version / standardversion medical version line line load load 1 2 3,25 ?6 detail a t echnical data of filter-components rated current / filter-type / filter-typ inductance / induktivit?ten capacitance / kapazit?ten r nennstrom (a) l1/l2 (mh) cx (nf) cy (nf) (m  ) 12 x 11 22 x 4 32 x 2,5 42 x 1,6 62 x 0,7 82 x 0,6 10 2 x 0,4 15 2 x 0,1 12 x 11 22 x 4 32 x 2,5 42 x 1,6 62 x 0,7 82 x 0,6 10 2 x 0,4 15 2 x 0,1 standard 47 2 x 2,2 e 47 e 1 medical 1) example rated current at +23 ?c 6,0 a ambient temperature +40 ?c correction factor / korrekturfaktor 1,08 chosen rated current at +40 ?c ambient temperature +40 ?c umgebungstemperatur 6 a x 1,08 = 6,5 a
www.schurter.com 128 power entry modules / ger?testecker-kombielemente 5145 attenuation loss standard version differential mode common mode medical version 1 a 1 a 6 a 2 a 8 a 3a 10 a 4 a 15 a 6 a 2 a 8 a 3a 10 a 4 a 15 a order code ta45 ( 2-pole rocker-switch without accessories) abtwf150c0 . 001 see table 1 t ype 5145 . order code (order example) wiring 0 without 1 with t ype of line filter 1 standard 3 medical rated current of line filter 1 1 (a) 5 6 (a) 2 2 (a) 6 8 (a) 3 3 (a) 7 10 (a) 4 4 (a) 8 15 (a) please note that schurter will establish an internal part number for logistical use in additional to the order code. the format of this internal part number is, for example 5145.0031.001 application note the rated current of the line filter must be equal or higher than the rated current of the circuit-breaker
www.schurter.com 129 power entry modules / ger?testecker-kombielemente 5145 abt w f 150 c0 colours switch front / rocker w black / schwarz white / weiss e b black / schwarz black / schwarz e 6 black / schwarz e orange transp. f embossed h printed / bedruckt white k printed / bedruckt black l printed / bedruckt white surface / illustration / colour of print rocker legend l o on off on off l o m printed / bedruckt black p printed / bedruckt white r printed / bedruckt black surface / illustration / colour of print without thermal overload protection: code c00 with thermal overload protection: rated current i n (a) rated current : without release: code c0 undervoltage release remote trip release p2 p1 u< p2 p1 b u< p2 p1 b a u< p2 p1 c ue za code rated voltage u n 2 3 4 240 v ac 230 v ac 120 v ac } i n = 16 a l o o o i i position of the rocker legend e.g f i n code 0,1 j01 0,2 j02 0,3 j03 0,4 j04 0,5 j05 0,6 j06 0,7 j07 0,8 j08 0,9 j09 1,0 j10 1,1 j11 1,2 j12 i n code 1,3 j13 1,4 j14 1,5 j15 1,6 j16 1,7 j17 1,8 j18 1,9 j19 2,0 j20 2,1 j21 2,2 j22 2,3 j23 2,5 j25 i n code 2,8 j28 3,0 030 3,5 035 4,0 040 4,5 045 5,0 050 6,0 060 6,5 065 7,0 070 7,5 075 8,0 080 9,0 090 i n code 10,0 100 11,0 110 12,0 120 13,0 130 14,0 140 15,0 150 t able 1 selection for type ta45 order example line switch 2-pole, rocker actuated quick connect terminal other types on request without illumination with illumination / 220240 v mit beleuchtung 110120 v 3 5 p 1 a diagram thermal overload protection without / ohne with 1-pole with 2-pole abc abt abd a02 a12 a32 a04 a14 a34 p2 p1 6 3 4 3 p2 p1 p2 p1 6 5 }


▲Up To Search▲   

 
Price & Availability of 5145ABTWFJ28C0311

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X