u ft 1 0 0 0 5 thru u f t 1 0 0 6 0 1 0 0 a mp s u p r e f a s t r ec o v e r y rectifier 50 to 6 00 v o lts features ? o pe r ating t e m pe r atu r e: - 5 5 c to +1 7 5 c ? sto r age t e m pe r atu r e: - 5 5 c to +1 7 5 c mcc part number maximum recurrent peak reverse voltage maximum rms voltage maximum dc blocking voltage u ft 1 0 0 05 50v 35v 50v u ft 1 0 01 0 100v 70v 100v u f t 1 0 0 2 0 200v 40v 200v u f t 10 0 40 400v 280v 400v u f t 10 06 0 600v 420v 600v www. mccsemi .com average forward current i f(av) 1 0 0 a t c = 1 2 5 c peak f o r w a r d su r ge cu r r ent ma x i m um in s tantaneous forward voltage maximum dc reverse current at rated dc blocking voltage i r 50 a t j = 25 c m ax i mum rat i n gs ? high su r ge capability ? low leakage ? low forward voltage drop ? high current capability ? s u p r e f as t s w i t c h in g f o r h i g h e ff i c i e n cy 1 . 2 5 v 1. 13 v 10 04 0 1 0 0 0 5 - 10 0 20 t y pi c a l j un c tion capa c itan c e maximum reverse recovery time 10 00 5 - 10 0 20 1 0 0 4 0 t rr 6 0ns 75 ns i f =0.5a, i r =1.0a, i r r =0.25a dimensions inch es mm dim min max min max note b .3 0 0 . 32 5 7 . 6 2 8 . 2 6 a 1 . 9 9 5 2 . 0 0 5 50 . 67 50 . 9 3 c . 4 9 5 . 5 0 5 1 2 . 57 1 2 . 83 e . 990 1 . 010 2 5 . 1 5 2 5 .65 f 2 .3 90 2 . 41 0 60 . 71 61 .2 1 g 1. 49 0 1 . 5 10 3 7 .85 38 . 35 h . 12 0 . 13 0 3.05 3.30 j -- -- - - . 4 0 0 --- -- - 1 0 . 16 k . 240 . 2 60 6.10 6.60 m . 3 3 0 . 35 0 8.38 8 . 90 n . 1 75 . 1 9 5 4.45 4.95 p . 0 35 . 0 45 0 . 89 1 . 1 4 ? po we r m o d l . 4 90 .5 1 0 1 2.45 12 . 9 5 h a l c n e b m q r d f g j p k q . 44 5 . 45 5 11 . 30 11 . 5 6 r . 89 0 . 910 22 . 61 23 . 11 d . 182 . 192 4 . 62 4 . 88 i i e lect r ical cha r acte r istics @ 2 5 c u nless o t he r w ise s p ecified i i fsm 1 0 0 0a 8.3 m s , half s i ne 1 0 0 05 - 1 00 20 i fm = 5 0 .0 a; t j = 25 c v f 6 m a t j = 1 25 c *pul s e t e s t: pul s e w i dth 30 0 s e c, d u t y c y c l e 2 % 1 0 06 0 90 ns 1 0 0 6 0 1 . 35 v 1 0 0 4 0 10 0 6 0 8 00 a 7 00 a c j 57 5 pf mea s u r ed at 1.0mh z , v r = 10 v 10 00 5 - 10 0 20 1 0 0 4 0 300 pf 1 0 0 6 0 2 7 5 pf om p on ent s 21 20 1 i t a sc a s t ree t ch at s w or th ! " # $ % ! " # mcc
average forward rectified current - amperes versus case te m pera t ure - c f i gure 2 for w ard dera t i ng curve 0 175 50 75 100 125 0 2 0 4 0 6 0 single phase, half wave 60hz resistive or inductive load amps c 150 8 0 1 0 0 12 0 j un c t i on capa c i t an c e - pf v e r s u s reverse voltage - volts instantaneous forward current - amperes versus instantaneous forward voltage - volts figure 1 typical forward characteristics 40 60 200 100 amps 0.6 0.8 1.0 1.2 1 .4 1.6 .1 .2 .4 .6 1 2 4 6 10 20 25 c volts figure 3 junction capacitance .1 .2 1.4 2 10 20 404 100 200 10 20 60 100 200 1000 pf volts 8 00 400 40 400 1000 t j =25 c u ft 10 00 5 thr n u f t 1 0 0 60 www. mccsemi .com mcc 10 0 40 10 00 5 - 1 0 0 20 2 0 00 5 - 2 0 0 20 2 0 0 40 2 0 0 60 10 0 60
uf t 1 0 0 05 thru u ft 10 0 60 www. mccsemi .com mcc instantaneous reverse leakage current - microamperes versus percent of rated peak reverse voltage - volts figure 4 typical reverse characteristics volts 40 60 1 0 00 100 amps 20 120 40 60 80 100 .1 .2 .4 .6 1 2 4 6 10 20 t j = 25 c 20 00 4 0 00 5 000 140 t j = 1 25 c 1 100 4 0 1 00 3 00 6 00 8 f i gure 5 peak forward surge current peak forward surge current - amperes versus number of cycles at 60hz - cycles amps cycles 2 6 10 20 60 80 40 7 00 8 00 1 0 00 1 0 00 5 - 1 0 0 2 0 10 0 6 0 10 0 4 0
|