(1/3) 002-01 / 20080817 / e9133_zrgs_00.fm ? all specifications are subject to change without notice. emc filters for ac power line for single-phase, mid-size box cased zrgs-00 series features excellent noise attenuation in the low range making it perfect emc prevention equipment for inverters. screw terminal has a spring which moves the washer up and has a safe design to prevent the screw from falling. it is a product conforming to rohs directive. applications power line noise prevention machine tools and nc control devices medical equipment such as mris other industrial equipment safety standards shapes and dimensions dimensions in mm case:plastic, block terminal: phillips head screw terminals, base: metal conformity to rohs directive part no. standard and standard no. u.s.a canada europe ul1283 csa c22.2 no.8 en60939 zrgs2003-00 e62388 lr76849c p08209003 zrgs2006-00 e62388 lr76849c p08209003 ZRGS2010-00 e62388 lr76849c p08209003 zrgs2016-00 e62388 lr76849c p08209003 zrgs2020-00 e62388 lr76849c p08209003 zrgs2030-00 e62388 lr76849c p08209003 ul csa nemko part no. a b c d e f g h zrgs2003-00 55 80 35 29.8 3 40 65 m4 zrgs2006-00 55 95 35 29.8 3 40 80 m4 ZRGS2010-00 55 95 35 29.8 3 40 80 m4 zrgs2016-00 55 95 35 29.8 3 40 80 m4 zrgs2020-00 55 95 35 29.8 3 40 80 m4 zrgs2030-00 55 95 35 29.8 3 40 80 m4 g 13.5 a c 13.5 f 2-?5.0 bolt h 2-?9.0 de b 1 2 4 3 conformity to rohs directive: this means that, in conformity with eu directive 2002/95/ec, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, pbb and pbde, have not been used, except for exempted applications.
(2/3) 002-01 / 20080817 / e9133_zrgs_00.fm all specifications are subject to change without notice. electrical characteristics typical electrical characteristics attenuation vs. frequency characteristics zrgs2003-00 zrgs2006-00 ZRGS2010-00 zrgs2016-00 zrgs2020-00 zrgs2030-00 part no. zrgs2003-00 zrgs2006-00 ZRGS2010-00 zrgs2016-00 zrgs2020-00 zrgs2030-00 rated voltage eac(v) 250 250 250 250 250 250 rated current(a) 3 6 10 16 20 30 test voltage eac (v) [between terminal and ground terminal] 2500 2500 2500 2500 2500 2500 insulation resistance (m ? ) [dc.500v,1min / between terminal and ground terminal] 100min. 100min. 100min. 100min. 100min. 100min. leakage current (ma)[250v 60hz] 1.0max. 1.0max. 1.0max. 1.0max. 1.0max. 1.0max. dc resistance (m ? ) 270max. 95max. 40max. 22max. 14max. 8max. operating temperature range ( c) [including self-temperature rise] ?25 to +85 ?25 to +85 ?25 to +85 ?25 to +85 ?25 to +85 ?25 to +85 with derating over(c) 555555555555 temperature rise ( c) 30max. 30max. 30max. 30max. 30max. 30max. attenuation frequency range (mhz)[+5 to +35 c] differential mode at 40db 0.3 to 30 0.3 to 30 0.3 to 30 0.5 to 30 0.5 to 30 0.7 to 30 common mode at 20db 0.1 to 30 0.1 to 10 0.2 to 10 0.3 to 10 0.5 to 10 2.0 to 10 weight (g) 195 255 265 265 265 265 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10 0.1 1 10 100 frequency ( mhz ) attenuation ( db ) differential mode common mode 0 ?100 ?90 ?80 ?70 ?60 ?50 ?40 ?30 ?20 ?10
(3/3) 002-01 / 20080817 / e9133_zrgs_00.fm all specifications are subject to change without notice. circuit diagram case gnd r: bleeder resistor 1 23 4 r r ground terminal ground terminal
|