  Datasheet File OCR Text:
  cs-2506 ? 09/01/06 ? page 1 of 2 e50498 ce69 csa lr31085 7150-1439:100 XAL-53 pull ring XAL-53 dimensions california state fire marshal contact block rating applications XAL-53 fire alarm stations are suitable for: ? hazardous areas due to the presence of flammable gases or vapors, combustible dusts or easily ignit- able fibers or flyings. ? installation at petroleum refineries, chemical and pet- rochemical plants, storage areas, and other process- ing facilities where hazardous substances are handled and stored. ? areas where emergency control of fire alarm or sig- nal circuits is required. features ? enclosure is made of copper-free aluminum alloy. ? conduit openings are 3/4" (19.05 mm) npt feed- through. ? red, textured powder epoxy paint finish is standard on box and cover and provides high visibility for alarm station. ? universal (1) normally open and (1) normally closed contact furnished standard. ? bilingual nameplates included per csa requirement. ? internal ground screw is standard. ? wiring range is #12 awg through #24 awg, solid or stranded. operation the alarm station is activated by lifting the front cover and pulling down ring. this quick, easy-to-use two- step process prevents unintentional operation. opera- tor is reset by depressing shaft and returning plate to original position. hazardous area classifications ? class i, divison 1 and 2, group c and d. ? class ii, division 1 and 2, group e, f, and g. ? class iii, hazardous locations. ? nema 7cd, 9efg. a c d c volts make amperes va break amperes va continuous carrying amperes volts make break continuous carrying amperes 120 60 7200 6.0 720 10 125 1.10 10 240 30 7200 3.0 720 10 250 0.55 10 480 15 7200 1.5 720 10 600 0.20 10 600 12 7200 1.2 720 10 xal - 53 explosion-proof pull station september 1, 2006 cs-2506 specifications and wiring information are provided for information only and are believed to be accurate. gamewell-fci assumes no responsibility for their use. data and design are subject to change without notice. installation and wiring instructions shipped with the product shall always be used for actual installation. for more information, contact gamewell-fci, a honeywell company. gamewell-fci 12 clintonville road northford, ct 06472-1610 phone: 203-484-7161 fax: 203-484-7118 www.gamewell-fci.com 5274acdc.tbl 5274dim1.tif 5274pho.jpg
page 2 of 2 ? cs-2506 ? 09/01/06 operational data this enclosure is made of cast, copper-free aluminum al- loy. it is suitable for: class i, groups c and d; class ii, groups e, f, and g; and class iii hazardous locations. all installations must comply with applicable local and/or na- tional electrical code. during installation, do not use looped wire under ter- minals. break wire run to provide supervision of con- nections. like all electromechanical devices, these control stations require occasional maintenance. parts may wear out or become defective due to adverse environmental conditions. see maintenance data below. maintenance data disconnect this device from the supplying circuit be- fore removing the cover. 1) to prevent corrosion, lubricant should be occasionally applied, as follows: ? killark? ?lubg? lubricant to box/cover flanges. ? dow corning? molykote? 33 grease, light consistency, to operator shaft. 2) keep all flanges clean and free of scratches. 3) some internal service parts are available. consult the killark? factory for parts breakdowns. killark ? is a registered trademark of hubbell?. dow corn- ing ? and molykote ? are registered trademarks of dow corn- ing corporation. product line information XAL-53 pull station, explosion-proof, n/o and n/c con- tacts. sba-10 backbox. contact arrangement not activated position activated position 5274con2.wmf 5274con1.wmf


▲Up To Search▲   

 
Price & Availability of XAL-53
Newark

Part # Manufacturer Description Price BuyNow  Qty.
XAL53
22H3445
Edwards Signaling Manual Station Explosion Proof |Edwards Signaling Products XAL53 50: USD900.5
25: USD1005.36
10: USD1091.7
5: USD1239.73
1: USD1393.93
BuyNow
0

DigiKey

Part # Manufacturer Description Price BuyNow  Qty.
XAL535033.000000K
800-XAL535033.000000KTR-ND
Renesas Electronics Corporation CLCC 5.00X3.20X1.10 MM, 2.54MM P 1000: USD1.81598
BuyNow
0

Avnet Americas

Part # Manufacturer Description Price BuyNow  Qty.
XAL535033.000000K
XAL535033.000000K
Renesas Electronics Corporation Low Phase Noise Quartz-Based PLL Oscillator 33MHz 6-Pin Surface Mount - Tape and Reel (Alt: XAL535033.000000K) 100000: USD1.5748
10000: USD1.612
8000: USD1.6492
6000: USD1.6864
4000: USD1.7236
2000: USD1.7608
1000: USD1.798
BuyNow
0

Mouser Electronics

Part # Manufacturer Description Price BuyNow  Qty.
XAL535033.000000K
972-AL535033B00000K
Renesas Electronics Corporation Standard Clock Oscillators XAL5 5032 HCMOS XO LOW JITTER 1000: USD1.81
RFQ
0

RS

Part # Manufacturer Description Price BuyNow  Qty.
XAL53
70485086
Edwards Signaling Manual Station Explosion Proof | Edwards Signaling XAL53 1: USD1407.87
5: USD1337.48
RFQ
0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X