mar. 2002 outline drawing mitsubishi hybrid ic M57146U-01 ipm power supply unit block diagram description M57146U-01 is an insulated dc-dc converter designed to drive the ipm. 4 outputs of 15vdc can obtain from an input of 220 ~ 380vdc. the terminals between inputs and outputs, and each outputs are insulated. features output ............................................... +15v, 50max3 +15v, 100max1 electrical isolation (between input and outputs) ........................................................... 1500vrms 1minute electrical isolation (between each outputs) ........................................................... 1500vrms 1minute application power supply for ipm drive dimensions: mm v in + v in control circuit v 01 + v 01 v 02 + v 02 v 03 + v 03 v 04 + v 04 cn1-1 cn1-3 cn2-2 cn2-1 cn3-8 cn3-7 cn3-5 cn3-4 cn3-1 cn3-2 76.0 0.7 65.0 0.7 31 2 12 1578 4 4.0 max 30.0 max 1.6 xxxx 4- 4.5 lot no. 5.0 5.0 5.0 5.0 cn1 cn2 cn3 5.0 5.0 5.0 5.0
mar. 2002 mitsubishi hybrid ic M57146U-01 ipm power supply unit maximum ratings (ta = 25 c, unless otherwise noted) v v mv v % v ma ma c c w vrms vrms 380 50 100 10 ~ 70 20 ~ 85 3.75 1500 1500 ratings symbol parameter conditions unit 220 14 14 14 14 15 15 15 15 50 50 50 50 50 0.7 0.7 0.7 73 380 16 16 16 16 symbol unit parameter test conditions limits min. typ. max. input voltage output current operating temperature storage temperature total output power electrical isolation between input and outputs electrical isolation between each outputs v i i l t opr t stg po viso1 viso2 vo1, vo2, vo3 vo4 no condensation no condensation sine wave voltage, 60hz, 1 minutes sine wave voltage, 60hz, 1 minutes recommended range io1 = 0 ~ 50ma, io2 = io3 = 0ma, io4 = 80ma io2 = 0 ~ 50ma, io1 = io3 = 0ma, io4 = 80ma io3 = 0 ~ 50ma, io1 = io2 = 0ma, io4 = 80ma io4 = 10 ~ 100ma, io1 = io2 = io3 = 0ma vo1 voltage change io1 = 30ma, io2 = io3 = 0ma, io4 = 80ma vo2 voltage change io2 = 30ma, io1 = io3 = 0ma, io4 = 80ma vo3 voltage change io3 = 30ma, io1 = io2 = 0ma, io4 = 80ma vo4 voltage change io1 = io2 = io3 = 0ma, io4 = 80ma vo1 voltage change io1 = 0 ~ 50ma, io2 = io3 = 0ma, io4 = 80ma vo2 voltage change io2 = 0 ~ 50ma, io1 = io3 = 0ma, io4 = 80ma vo3 voltage change io3 = 0 ~ 50ma, io1 = io2 = 0ma, io4 = 80ma vo4 voltage change io4 = 10 ~ 100ma, io1 = io2 = io3= 0ma v in = 300v, io1 = io2 = io3= 30ma, io4 = 80ma v i vo1 vo2 vo3 vo4 reg-i reg-l input voltage output voltage line regulation load regulation efficiency electrical characteristics (v in = 220 ~ 380v, ta = 25 c, unless otherwise noted)
mar. 2002 mitsubishi hybrid ic M57146U-01 ipm power supply unit application example available ipm pm10csj060 pm15csj060 pm20csj060 pm30csj060 pm15ctm060 pm15ctm060-3 pm20ctm060 pm20ctm060-3 pm30ctj060 pm30ctj060-3 pm30rsf060 ac200~240v + v in + v up1 v upc v vp1 v wp1 u p v vpc v wpc v p w p u n v n w n ipm f 0 v n1 ex. pm15/20ct m060(-3) v o 1+ v o 1 v o 2 v o 2+ v o 3+ v o 4+ m57146u v o 3 v o 4 v in + + + +
|