Part Number Hot Search : 
CJU30N10 MSD4B13C X76F101 PT2332 KI5473DC MSC23 SBM17PT FR105
Product Description
Full Text Search
 

To Download MFSYS25 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Intel(R) Modular Server System MFSYS25/MFSYS35
Technical Product Specification
Intel order number E15155-006
Revision 1.3 November, 2008 Enterprise Platforms and Services Division
Revision History
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Revision History
Date July, 2007 September, 2007 February, 2008 June, 2008 November, 2008 Revision Number 0.88 1.0 1.1 1.2 1.3 Modifications Initial release. Updated. Updated. Updated Power Budget of Hardware Components, Table 5. Added 3.5-inch drive bay information for the Intel(R) Modular Server System MFSYS35. Updated System Details, power and heat specifications
Disclaimers
Information in this document is provided in connection with Intel(R) products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" inches or "undefined" Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The Intel(R) Modular Server System MFSYS25/MFSYS35 may contain design defects or errors known as errata, which may cause the product to deviate from published specifications. Current characterized errata are available on request. Intel Corporation server baseboards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. Intel and Xeon are trademarks or registered trademarks of Intel Corporation. *Other brands and names may be claimed as the property of others. Copyright (c) Intel Corporation 20072008
ii Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Table of Contents
Table of Contents
Product Overview................................................................................................................. 1 System Overview.................................................................................................................. 2 2.1 Introduction .............................................................................................................. 2 2.2 External Chassis Features - Front .......................................................................... 5 2.2.1 Compute Module ..................................................................................................... 6 2.2.2 Storage Enclosure ................................................................................................... 6 2.2.3 I/O Cooling Module .................................................................................................. 6 2.3 External Chassis Features - Rear........................................................................... 7 2.3.1 Power Supply Module.............................................................................................. 7 2.3.2 I/O Slots ................................................................................................................... 7 2.3.3 Chassis Management Module ................................................................................. 8 2.3.4 Main Cooling Module ............................................................................................... 8 2.4 Internal Chassis Features........................................................................................ 8 2.4.1 Midplane Board...................................................................................................... 10 2.4.2 Storage Interposer Board ...................................................................................... 11 2.5 Mounting and Service Features............................................................................. 11 2.5.1 Chassis .................................................................................................................. 11 2.5.2 Rails....................................................................................................................... 11 2.6 Server Management .............................................................................................. 11 2.6.1 Chassis Management Module ............................................................................... 12 2.6.2 Compute Module Management ............................................................................. 12 2.7 Reliability, Availability, Serviceability, Usability, Manageability (RASUM) ............. 13 3. System Details.................................................................................................................... 14 3.1 Specifications......................................................................................................... 14 3.1.1 Environmental Specifications Summary ................................................................ 14 3.1.2 Physical Specifications Summary.......................................................................... 14 3.1.3 Power Specifications Summary ............................................................................. 15 3.2 Chassis .................................................................................................................. 16 3.3 Midplane Board...................................................................................................... 19 3.3.1 Mechanical Outline ................................................................................................ 19 3.3.2 3D Renderings....................................................................................................... 20 3.4 Compute Module ................................................................................................... 21 3.4.1 Introduction ............................................................................................................ 21 3.4.2 Drawings................................................................................................................ 22 3.5 Chassis Management Module ............................................................................... 22 3.5.1 Introduction ............................................................................................................ 22 3.5.2 Mechanical Outline ................................................................................................ 23 3.5.3 Block Diagram ....................................................................................................... 24 1. 2.
Revision 1.3 Intel order number E15155-005
iii
Table of Contents
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.5.4 Drawings................................................................................................................ 24 3.5.5 Architectural Overview........................................................................................... 25 3.6 Ethernet Switch Module......................................................................................... 26 3.6.1 Introduction ............................................................................................................ 26 3.6.2 Mechanical Outline ................................................................................................ 26 3.6.3 Block Diagram ....................................................................................................... 27 3.6.4 Architectural Overview........................................................................................... 27 3.7 Storage Controller Module..................................................................................... 28 3.7.1 Storage Subsystem Introduction............................................................................ 28 3.7.2 Mechanical Outline ................................................................................................ 28 3.7.3 Storage Controller Module View ............................................................................ 29 3.7.4 Architectural Overview........................................................................................... 29 3.8 Power Supply Module............................................................................................ 30 3.9 Jumpers and LEDs ................................................................................................ 31 4. Product Regulatory Requirements ................................................................................... 32 4.1 Product Regulatory Compliance ............................................................................ 32 4.1.1 Product Safety Compliance ................................................................................... 32 4.1.2 Product EMC Compliance - Class A Compliance .................................................. 32 4.1.3 Product Ecology Compliance................................................................................. 33 4.1.4 Certifications / Registrations / Declarations ........................................................... 33 4.2 Product Regulatory Compliance Markings ............................................................ 33 4.3 Regulated Specified Components ......................................................................... 38 4.4 Electromagnetic Compatibility Notices .................................................................. 39 4.4.1 FCC Verification Statement (USA) ........................................................................ 39 4.4.2 ICES-003 (Canada) ............................................................................................... 40 4.4.3 Europe (CE Declaration of Conformity) ................................................................. 40 4.4.4 VCCI (Japan) ......................................................................................................... 41 4.4.5 BSMI (Taiwan) ....................................................................................................... 41 Glossary..................................................................................................................................... 43 Reference Documents .............................................................................................................. 46
iv Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
List of Figures
List of Figures
Figure 1. Intel(R) Modular Server System MFSYS25 Wiring Diagram............................................. 3 Figure 2. Intel(R) Modular Server System MFSYS35 Wiring Diagram............................................. 4 Figure 3. Front View of Server Platform........................................................................................ 5 Figure 4. Rear View of Server Platform ........................................................................................ 7 Figure 5. View of Intel(R) Modular Server System MFSYS25 System Board Connectivity.............. 9 Figure 6. View of Intel(R) Modular Server System MFSYS35 System Board Connectivity............ 10 Figure 7. Server Management Connectivity................................................................................ 12 Figure 8. Front View of Empty Intel(R) Modular Server System MFSYS25 ................................... 16 Figure 9. Front View of Empty Intel(R) Modular Server System MFSYS35 ................................... 17 Figure 10. Rear View of Empty Intel(R) Modular Server System MFSYS25.................................. 18 Figure 11. Rear View of Empty Intel(R) Modular Server System MFSYS35.................................. 18 Figure 12. Midplane Board Mechanical Outline (Front View) ..................................................... 19 Figure 13. Front View of Midplane Board ................................................................................... 20 Figure 14. Rear View of Midplane Board .................................................................................... 21 Figure 15. Front View of Compute Module ................................................................................. 22 Figure 16. Chassis Management Module Board Outline (Top View) .......................................... 23 Figure 17. Chassis Management Module Block Diagram........................................................... 24 Figure 18. Front View of Chassis Management Module ............................................................. 25 Figure 19. Ethernet Switch Module Mechanical Outline (Top View)........................................... 26 Figure 20. Ethernet Switch Module Block Diagram .................................................................... 27 Figure 21. Mechanical Outline of Storage Controller Module Board........................................... 28 Figure 22. Front View of Storage Controller Module................................................................... 29
Revision 1.3 Intel order number E15155-005
v
List of Tables
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
List of Tables
Table 1. Server Platform Feature List ........................................................................................... 2 Table 2. Environmental Specifications Summary ....................................................................... 14 Table 3. Physical Specifications of Chassis................................................................................ 14 Table 4. Physical Dimensions of Hardware Components ........................................................... 15 Table 5. Power Budget of Hardware Components ..................................................................... 15 Table 6. Power and Heat Dissipation Specifications of Chassis................................................. 15
vi Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Overview
1.
Product Overview
This product specification details the features of the Intel(R) Modular Server System MFSYS25/MFSYS35. This product is designed to serve the small to medium business environment. Primary design considerations include ease of use, reliability, low cost, modularity, and remote management. The Intel(R) Modular Server System MFSYS25/MFSYS35 supports up to six dual-processor compute modules, or a total of 12 Multi-Core Intel(R) Xeon(R) 5000 sequence processors. The chassis also incorporates features that clearly distinguish it as an easy-to-use and highly available server platform. Building on previous server platforms, the Intel(R) Modular Server System MFSYS25/MFSYS35 includes redundant storage and networking, in addition to the enterprise features of hot-swap power, cooling, and hard disk drives. Advanced server management features remotely monitor and manage the server. This document is organized into four sections: Section 1: Product Overview This section provides an overview of the product. Section 2: System Overview This section provides an overview of the system hardware. Section 3: System Details This section provides details of the various hardware components specific to the server platform. Section 4: Product Regulatory Requirements This section describes system compliance to regulatory specifications.
Revision 1.3 Intel order number E15155-005
1
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
2.
System Overview
This section provides an overview of the features of the Intel(R) Modular Server System MFSYS25/MFSYS35.
2.1
Introduction
The platform supports six compute modules providing sockets for up to 12 Multi-Core Intel(R) Xeon(R) processors 5000 sequence, up to 192 GB of memory (using 4-GB DIMMs), up to fourteen hot-swap 2.5-inch SAS hard disk drives in the Intel(R) Modular Server System MFSYS25 or up to six hot-swap 3.5-inch SAS/SATA hard disk drives in the Intel(R) Modular Server System MFSYS35, an integrated server management module, redundant Ethernet switches and redundant storage controllers. The server ships configured for rack mounting, but may be mounted in a pedestal configuration. The following table lists and briefly describes the features of the Intel(R) Modular Server System MFSYS25/MFSYS35.
Table 1. Server Platform Feature List
Feature Compact, high-density system Configuration flexibility Description Rack-mount server with a height of 6U (10.5 inches) and a depth of 28 inches (706 mm) Shared storage hard drive bay supporting up to fourteen (14) 2.5-inch SAS hard drives in the Intel(R) Modular Server System MFSYS25 and up to six (6) 3.5-inch SAS/SATA hard drives in the Intel(R) Modular Server System MFSYS35. Up to six (6) compute modules Optional secondary Ethernet switch module Optional secondary storage controller Tool-less design features Front access to optional hot-swap hard disk drives Rear access to I/O slots, cooling, and hot-swap power supplies Status and fault indicator LEDs Front viewable compute module ID LEDs Color-coded parts to identify hot-swap and non-hot-swap serviceable components Four 1000-W power supplies in a redundant (3+1) configuration with separate power cords Up to six compute modules Redundant networking and storage Redundant cooling Remote management Extensive system sensors and monitoring Remote diagnostics support via serial and LAN ports Web management console KVM console redirection The front of each individual compute module provides video, USB, a power button, and status LEDs that allow local monitoring and managing of the individual compute module.
Serviceability
Availability
Manageability
2 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Feature Cooling Description The cooling subsystem consists of three cooling zones * * I/O module cooling Hard drives and power supplies
System Overview
* Compute modules Each cooling zone contains dedicated hot-swap fan modules. Each fan module contains a status LED to indicate a fan failure. The front- and rear-accessible fan modules connect directly to the system midplane board. Easy to use Full system management via Web browser Configuration wizards assist in setup of storage and network
Figure 1. Intel(R) Modular Server System MFSYS25 Wiring Diagram
Revision 1.3 Intel order number E15155-005
3
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Figure 2. Intel(R) Modular Server System MFSYS35 Wiring Diagram
4 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Overview
2.2
External Chassis Features - Front
Figure 3 shows the front view of the platform with all modules populated.
B A
C
D
Item A B Description Compute modules (six) Storage enclosure: (R) 14 hot-swap 2.5-inch SAS hard disk drives - Intel Modular Server System MFSYS25 only 6 hot-swap 3.5-inch SAS/SATA hard disk drives - Intel(R) Modular Server System MFSYS35 only I/O cooling module System Fault LED (amber)
AF002657
C D
Figure 3. Front View of Server Platform
Revision 1.3 Intel order number E15155-005
5
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
2.2.1
(R)
Compute Module
The Intel Modular Server System MFSYS25/MFSYS35 supports up to six compute modules. Each of these general-purpose servers provides the following minimum features: Processor(s) Memory Integrated Baseboard management controller Network interface Each server connects to the chassis management module, storage controllers and switch modules via the midplane board. The midplane also distributes the 12V power from the power supplies to the compute modules. The servers connect to the shared storage (14 SAS drives in the Intel(R) Modular Server System MFSYS25 and 6 SAS/SATA drives in the Intel(R) Modular Server System MFSYS35) via the storage controller(s) in the rear of the chassis. See the individual Intel(R) Compute Module Technical Product Specification for model-specific information about your compute module(s).
2.2.2
(R)
Storage Enclosure
The Intel Modular Server System MFSYS25/MFSYS35 supports an optional hard disk drive storage enclosure and has the following minimum features: Bays for 14 hot-swap 2.5-inch SAS hard disk drives in the Intel(R) Modular Server System MFSYS25 and six (6) 3.5-inch SAS/SATA hard drives in the Intel(R) Modular Server System MFSYS35 At least one storage controller in an I/O slot Because hard disk drives have different cooling, power, and vibration characteristics, Intel validates specific hard disk drive types in the platforms. See the Intel(R) Modular Server System MFSYS25/MFSYS35 Tested Hardware and Operating System List for a list of qualified drives.
2.2.3
I/O Cooling Module
The I/O cooling module consists of six fans that operate in a (3 + 3) cooling redundancy in a hot-swap module with power and failure indicators. These fans provide cooling for all I/O modules. This module is accessible from the front of the system even though it cools the I/O modules in the rear of the system.
6 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Overview
2.3
External Chassis Features - Rear
C
The following figure shows the rear view of the platform with all modules populated.
A B
E
Item A B C D E Description Power supply units (four, 3+1) Main cooling modules (required) Ethernet switch modules Storage controllers Management module (required)
D
AF002564
Figure 4. Rear View of Server Platform
2.3.1
Power Supply Module
Four hot-swap power supply modules are installed in the right rear of the chassis. Each supply has its own AC input power connector and is rated at 1000 W over an input range of 100-240 VAC. Each power supply includes two fans that provide cooling for optional hot-swap disk drives. See Section 3.8 for more details on the power supply module.
2.3.2
I/O Slots
The middle-rear of the chassis can accommodate up to four expansion modules. See the following sections for a description of the two I/O modules currently offered. 2.3.2.1 Ethernet Switch Module
The chassis can accommodate up to two hot-swap Ethernet switch modules. Each switch has ten uplink ports on the rear panel in addition to two ports routed to each compute module. One switch module is the minimum configuration for external networking, with a second switch module allowing network redundancy.
Revision 1.3 Intel order number E15155-005 7
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
See Section 3.6 for a description of this module.
2.3.2.2
Storage Controller Module
The chassis can accommodate up to two hot-swap storage controller modules to support the external hard disks in the front storage enclosure. One storage controller is the minimum configuration, with a second storage controller allowing storage controller redundancy. Storage controller failures are automatically detected and hard drive access is maintained through the operational storage controller. See Section 3.7 for a description of this system.
2.3.3
Chassis Management Module
The chassis management module, installed in the middle-rear of the chassis amid the four I/O slots, provides an Internet browser interface that allows for configuration and management of the entire Intel(R) Modular Server System MFSYS25/MFSYS35. This module is not redundant, but the system continues to operate normally should this module fail although any changes to the system configuration cannot be made until the failed chassis management module is replaced. See Section 3.5 for a description of this module.
2.3.4
Main Cooling Module
Two hot-swap cooling modules are installed on the left rear of the chassis. Each cooling module contains two redundant fans that operate in a (1+1) cooling redundancy. Cooling module 1 cools compute modules 1-3; cooling module 2 cools compute modules 4-6.
2.4
Internal Chassis Features
The following figures provide an internal view of how the Intel(R) Modular Server System MFSYS25/MFSYS35 system boards are connected.
8 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Overview
Item A B C D E F G H I
Description Server board 14-drive backplane Interposer board (connects drive backplane to midplane) I/O fan controller Midplane board Compute module fan controllers Storage controller boards Switch module boards Chassis management module board
Figure 5. View of Intel(R) Modular Server System MFSYS25 System Board Connectivity
Revision 1.3 Intel order number E15155-005
9
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Item A B C D E F G H I
Description Server board 6-drive backplane Interposer board (connects drive backplane to midplane) I/O fan controller Midplane board Compute module fan controllers Storage controller boards Switch module boards Chassis management module board
Figure 6. View of Intel(R) Modular Server System MFSYS35 System Board Connectivity
2.4.1
Midplane Board
The midplane board mounts vertically in the middle of the system and provides power and I/O signaling, both high-speed and low-speed, to all chassis subassemblies and options. This board is considered to be a part of the chassis and cannot be replaced. For this reason, there are no active components on this board.
10 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Overview
2.4.2
Storage Interposer Board
The interposer board mounts vertically in the front left of the system and connects the midplane to the hot-swap backplane in the storage enclosure. Each compute module connects to the storage controller with a non-RAID SAS controller, with the storage controller providing the RAID functionality.
2.5
2.5.1
Mounting and Service Features
Chassis
The platform utilizes a standard 19-inch EIA chassis, 6U high by 28 inches deep. The chassis can be rack-mounted or used as a pedestal system. Rack mounting the platform requires a space of 6U high by 19 inches wide by 34 inches deep, with additional six inches required for cable management. When used in a rack, the chassis may be mounted with an optional rail kit. Pedestal operation requires the installation of six rubber feet to the bottom of the chassis. The 6U height is defined by standard EIA rack units, where 1U equals 1.75 inches. The 28-inch depth is measured from the front mounting flange to the back of the I/O slots. This measurement does not include cables or the bezel.
2.5.2
Rails
The platform accommodates rails to mount the chassis into a standard 19-inch rack. The Intel(R) Modular Server System MFSYS25/MFSYS35 uses fixed rails. All customer-accessible components provide either front or rear access. The rails attach to the rack using a tool-less mechanism. The system rests on the shelves of the rails and attaches to the rack using the integrated thumbscrews on the front flanges of the system. No loose hardware is needed.
2.6
Server Management
The management of all components in the system can be done through the chassis management module. This module provides a browser-based management interface that allows the configuration and management of all modules. As part of the compute module manageability, the chassis management module provides remote access (such as connectivity via Ethernet) to Keyboard-VDU-Mouse (KVM), USB media and serial console. The management subsystem conforms to the IPMI v2.0 Specification for communication within the chassis (such as between the chassis management module and other system components). SNMP is supported by the chassis management module for external system management.
Revision 1.3 Intel order number E15155-005
11
System Overview
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Clear Bay: Chassis Management Connections
I2C BUS 10/100Mbps Ethernet SPI BUS
PSU PSU
I2C BUS_0
I2C BUS_0
I2C BUS_1
I2C BUS_1
I/O FAN MODULE
STORAGE
I2C BUS_2
Ethernet VLAN in-band Ethernet VLAN in-band
SERVER COMPUTE MODULE
10/100Mbps Ethernet
SERVER COMPUTE MODULE
I2C BUS_2
Ethernet VLAN in-band
SERVER COMPUTE MODULE
SWITCH
HDD Backplane
SAS EXPANDER
I2C BUS_3
INTERPOSER
SAS EXPANDER
I2C BUS_4
I2C BUSSES
I2C BUS MANAGEMENT 10/100 Ethernet
7 Busses 5 Used w/ SMB
SPI Bus
FRU
I2C BUS_2
NVMEM SWITCH Ethernet VLAN in-band Ethernet VLAN in-band I2C BUS_2 STORAGE Ethernet VLAN in-band SERVER COMPUTE MODULE
SERVER COMPUTE MODULE
SERVER COMPUTE MODULE
PSU PSU
I2C BUS_0 I2C BUS_0
I2C BUS_1
SYSTEM FAN MODULE
I2C BUS_1
SYSTEM FAN MODULE
Figure 7. Server Management Connectivity
2.6.1
Chassis Management Module
The main controller in the chassis management module is an Intel(R) XScale IXP425 microcontroller that runs Linux to provide a robust operating environment. The service processor provides IPMI communication within the system in addition to the user interface used to manage the system over Ethernet. See Section 3.5 for a description of this board.
2.6.2
Compute Module Management
Each compute module contains an Integrated Baseboard Management Controller (BMC) that is responsible for all management local to the module, including power control, reset, sensor reading, remote KVM, remote media and remote serial console. The Integrated BMC also gathers events to be stored in the server event log. However, the compute module's Integrated BMC is managed by the chassis management module and must communicate with the chassis management before providing any of these management features. This architecture allows the chassis management module to control the security of all components in the system.
12 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Overview
2.7
Reliability, Availability, Serviceability, Usability, Manageability (RASUM)
The platform supports the following reliability, availability, serviceability, usability and manageability (RASUM) features: Reliability features Voltage and temperature monitoring throughout the system Availability features Hot-plug compute modules Hot-spare compute modules Redundant hot-swap power supply modules Redundant hot-swap system fans Hot-swap SAS hard drives Optional teaming and failover Ethernet ports Serviceability features Tool-less installation and removal of major sub-assemblies Color-coded parts to identify serviceable components Green: To identify hot-swap or hot-plug components Blue: To identify non-hot-swap components Compute module ID buttons and LEDs LED indicators for system health, configured options, and activity Usability features Tool-less design features External access to hot-swap hard disk drives, power supplies, LEDs and switches Front viewable compute module ID LEDs Color-coded parts to identify hot-swap and non-hot-swap serviceable components Manageability features Remote management via serial and LAN IPMI 2.0 compliance Remote management via KVM and dedicated LAN All subsystems are connected by a server management I2C bus to satisfy the system RASUM requirements.
Revision 1.3 Intel order number E15155-005
13
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3. System Details
3.1
3.1.1
Specifications
Environmental Specifications Summary
The following table describes the environmental specifications of the Intel(R) Modular Server System MFSYS25/MFSYS35
Table 2. Environmental Specifications Summary
Environment Temperature operating Temperature non-operating Altitude Humidity non-operating Vibration non-operating Shock operating Shock non-operating Safety Emissions Specification 50F to 95F -40F to 158F -100 to 5,000 ft
10C to 35C -40C to 70C -30 to 1,500 m
95%, non-condensing at temperatures of 25C (77F) to 30C (86F) 2.2 g, 10 minutes per axis on each of the three axes Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes Trapezoidal, 25 G, two drops on each of six faces V : 175 inches/sec on bottom face drop, 90 inches/sec on other 5 faces UL60 950, CSA60 950, AS/NZS 3562, GB4943-1995, EN60 950 and 73/23/EEC, IEC 60 950, EMKO-TSE (74-SEC) 207/94, GOST-R 50377-92 Certified to FCC Class A; tested to CISPR 22 Class A, EN 55022 Class A and 89/336/EEC, VCCI Class A, AS/NZS 3548 Class A, ICES-003 Class A, GB9254-1998, MIC Notice 1997-42 Class A, GOST-R 29216-91 Class A, BSMI CNS13438 Verified to comply with EN55024, CISPR 24, GB9254-1998, MIC Notice 1997-41, GOST-R 50628-95 Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without physical damage Sound power: < 7.0 BA at ambient temperature < 23 C measured using the Dome Method GOST MsanPiN 001-96
Immunity Electrostatic discharge Acoustic
3.1.2
Physical Specifications Summary
The following table describes the physical specifications of the Intel(R) Modular Server System MFSYS25/MFSYS35.
Table 3. Physical Specifications of Chassis
Specification Height - 6U Width Depth Weight (full configuration) Value 261.4 mm 444.4 mm 720.2 mm 85 kg
10.3 inches 17.5 inches 28.4 inches 187 lbs
The following table describes the physical dimensions of the Intel(R) Modular Server System MFSYS25/MFSYS35 and all components.
14 Intel order number E15155-005 Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
Table 4. Physical Dimensions of Hardware Components
Module Chassis Compute module CMM I/O Storage Hard drive bay Power supply module Main cooling module I/O cooling module Height Width 444.4 mm 279.4 mm 167.6 mm 167.6 mm 167.6 mm 130.2 mm 115 mm 126.0 mm 132.6 mm Length 720.2 mm 420.3 mm 295.9 mm 295.9 mm 295.9 mm 419.1 mm 286.3 mm 291.9 mm 416.9 mm
261.4 mm
41.7 mm 25.0 mm 38.0 mm 32.0 mm 182.5 mm 53.3 mm 126.6 mm 49.4 mm
3.1.3
Power Specifications Summary
The following table provides a summary of the 12V power budget for all modules in the Intel(R) Modular Server System MFSYS25/MFSYS35.
Table 5. Power Budget of Hardware Components
Subsystem Compute module Mezzanine card Chassis management module I/O Switch Storage module 2.5/3.5-inch SAS drives Chassis Power supply blank System Total Power subsystem spec 3000 W 12V Budget 406 W 5W 5W 40 W 48 W 140 W 188 W 26 W
The following table provides a summary of the power and heat dissipation specifications for the Intel(R) Modular Server System MFSYS25/MFSYS35.
Table 6. Power and Heat Dissipation Specifications of Chassis
Power Supply Input Power Supply Output System Power Input System Power Output System Power System Heat Dissipation System Heat Dissipation 1240 W 1050 W 3720 W 3150 W 100 V - 127 V, 200 V - 240 V 3720 W (12,701 BTUH) maximum 428 W (1461 BTUH) minimum
Revision 1.3 Intel order number E15155-005
15
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.2
Chassis
The Intel(R) Modular Server System MFSYS25/MFSYS35 design accommodates multiple generations of compute modules, I/O modules, and storage controllers without the need to upgrade or modify the chassis or the midplane board. This strategy allows the system to be in use for many years with only the occasional upgrade of front and/or rear components as new technologies become available. The following two figures show the front view of an empty Intel(R) Modular Server System MFSYS25/MFSYS35. Note that the hard drive bay is installed and the hard drive backplane is visible on the left side of the chassis. The midplane board is also installed and is visible through the empty compute module bay area.
HDD Backplane
Midplane
Figure 8. Front View of Empty Intel(R) Modular Server System MFSYS25
16 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
Figure 9. Front View of Empty Intel(R) Modular Server System MFSYS35
Revision 1.3 Intel order number E15155-005
17
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
The following two figures show the rear view of an empty Intel(R) Modular Server System MFSYS25/MFSYS35. The midplane is installed and is visible through the empty I/O and power supply module areas.
Figure 10. Rear View of Empty Intel(R) Modular Server System MFSYS25
Figure 11. Rear View of Empty Intel(R) Modular Server System MFSYS35
18 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
3.3
Midplane Board
This section describes the platform's midplane board. The midplane is the central board that connects to all removable modules. The midplane board, like the chassis, is designed to accommodate multiple generations of compute modules, I/O modules and storage controllers without the need to upgrade or modify the board. The connectors and electrical routing of the midplane board have been designed to support future, higher speed technologies up to 10 Gb/s.
3.3.1
Mechanical Outline
The following figure shows the mechanical outline drawing of the platform's midplane board.
Figure 12. Midplane Board Mechanical Outline (Front View)
Revision 1.3 Intel order number E15155-005
19
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.3.2
3D Renderings
This section contains perspective views of the midplane board.
Figure 13. Front View of Midplane Board
20 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
Figure 14. Rear View of Midplane Board
3.4
Compute Module
This section describes the platform's compute module at a high level. Refer to the Intel(R) Compute Module MFS5000SI Technical Product Specification for additional details.
3.4.1
(R)
Introduction
The Intel Modular Server System MFSYS25/MFSYS35 architecture allows new compute modules to be developed around future processor/chipset combinations without any change to the rest of the system. Given that processor/chipset improvements have occurred more frequently than other technologies, such as I/O and storage, the compute module should be updated more often than other components in the system.
Revision 1.3 Intel order number E15155-005
21
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.4.2
Drawings
This section contains perspective views of the compute module. The following figure shows the front view of the module.
Figure 15. Front View of Compute Module
3.5
Chassis Management Module
This section describes the chassis management module (CMM) in the Intel(R) Modular Server System MFSYS25/MFSYS35.
3.5.1
Introduction
The server platform's chassis management module provides chassis-wide system management. It interfaces with all system components either via the I2C bus or via the Intel(R) Ethernet Switch Module. (The CMM connects via ethernet directly to the storage controller module(s) and the Intel(R) Ethernet Switch Module(s), and indirectly to the compute modules. There are no ethernet connections to the power supply modules, cooling modules, or LED boards.) The main components of the CMM are the IXP-425 microcontroller, which runs the Linux OS in addition to the built-in server control GUI, and the FPGA, which provides IC bus expansion among other functionality.
22 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
3.5.2
Mechanical Outline
Figure 16. Chassis Management Module Board Outline (Top View)
Revision 1.3 Intel order number E15155-005
23
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.5.3
Block Diagram
The following block diagram divides the chassis management module into physical and functional blocks. Arrows represent buses and signals. Blocks represent the physical and functional circuits. The following figure illustrates the general architecture of the chassis management module.
Figure 17. Chassis Management Module Block Diagram
3.5.4
Drawings
The following figure shows the front view of the CMM.
24 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
Figure 18. Front View of Chassis Management Module
3.5.5
Architectural Overview
The chassis management module provides configuration and management capabilities for the entire Intel(R) Modular Server System MFSYS25/MFSYS35. The CMM runs the Web browseraccessible Server Control. The 10/100 Ethernet port on the front panel of the CMM provides the main interface to the Intel(R) Modular Server System MFSYS25/MFSYS35. The CMM runs the Linux operating system in addition to the built-in server control GUI application. Through the GUI, the customer can configure and manage any system component. Refer to the Intel(R) Modular Server System MFSYS25/MFSYS35 User Guide for more details on how to manage the system. The CMM monitors platform management events and logs their occurrence. This includes events such as over-temperature and over-voltage conditions, fan failures, etc. The CMM also provides the interface to this monitored information so that system management software can poll and retrieve the present status of the platform. The following is a list of the major functions of the CMM: System power control Storage controllers Ethernet switch modules Compute modules System initialization System fan management System Event Log (SEL) interface FRU inventory Event message generation and reception Serial over LAN (SOL) Sensor monitoring
Revision 1.3 Intel order number E15155-005 25
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Temperature Voltage Fan speed Processor status Power supplies IPMB communication interface Checks and forces automatic update of firmware of newly installed system boards to versions stored in the SD (secure digital) card on the midplane. CMM GUI provides remote KVM to the compute modules External serial port connector for local/remote management access External Ethernet connector for local/remote management
3.6
3.6.1
Ethernet Switch Module
Introduction
(R)
The Intel Ethernet Switch Module (ESM) provides ethernet connectivity for the CMM to the compute modules and for the compute modules to an external network.
3.6.2
Mechanical Outline
The following figure shows the mechanical outline of the ESM.
Figure 19. Ethernet Switch Module Mechanical Outline (Top View)
26 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
3.6.3
Block Diagram
Figure 20. Ethernet Switch Module Block Diagram
3.6.4
Architectural Overview
The ESM provides networking and switch functions to the compute modules. Each compute module is capable of accessing up to two ESMs via point-to-point links across the midplane. The ESM has ten (10) 1000BaseT external links to the outside, two (2) internal 10 Gbps XAUI links (one to the other ESM and one to the storage controller), twelve (12) internal point-to-point 1Gbps serializer/deserializer (SerDes) links (two to each compute module), one point-to-point internal 10/100 Mbps link to the CMM, and one IC interface to the CMM (for the CMM to configure and control the ESM).
Revision 1.3 Intel order number E15155-005
27
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
3.7
3.7.1
Storage Controller Module
Storage Subsystem Introduction
(R)
The Intel Modular Server System MFSYS25/MFSYS35 enables up to six diskless compute modules to interface via SAS connections to one or two (for redundancy) internal storage controller modules. The storage controller modules include RAID and storage virtualization functionality with connections to back-end shared internal SAS disk drives. Connectivity between the storage controller modules and the disk drive backplane is achieved via an interposer card to a 14-drive backplane in the Intel(R) Modular Server System MFSYS25 and a 6drive backplane in the Intel(R) Server System MFSYS35. In combination, these components allow up to 14 2.5-inch SAS drives in the Intel(R) Modular Server System MFSYS25 and up to 6 3.5-inch SAS/SATA drives in the Intel(R) Modular Server System MFSYS35 to be shared between all compute modules. The CMM is used to configure drive arrays and to match LUNs to specific compute modules.
3.7.2
Mechanical Outline
Figure 21. Mechanical Outline of Storage Controller Module Board
28 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
3.7.3
Storage Controller Module View
Figure 22. Front View of Storage Controller Module
3.7.4
3.7.4.1
Architectural Overview
Storage Controller Module Interface
The Interposer SAS signals from the storage controller module (SCM) originate from the LSI* 1068 and PM8399* devices. A hardware reset line for each expander originates from each SCM. One SAS expander on the Interposer is managed by one SCM; the second expander is managed by the second SCM (if installed). An IC bus connects the SCM(s) to the Interposer VPD SEEPROM and each expander. The SCM(s) can retrieve hardware monitor and drive backplane IDROM information from the expanders, which are connected via IC to these devices. Disk drive status is communicated via SES pages to the expanders from the RAID stack in the SCM, and this status is exported to GPIO LED signals, one for each disk drive. One overall RAID status LED is also sent via SES and exported to a single LED. Expander firmware can be downloaded from the SCM. 3.7.4.2 Interposer Card Functionality
SAS expander-1 provides connectivity to all disk drive "A" ports; SAS expander-2 provides connectivity to all disk drive "B" ports. "A" port SAS traffic originates only from SCM-1, and "B" port SAS traffic originates only from SCM-2. The SAS connection from SCM-1 to expander-2 (and SCM-2 to expander-1) is intended for high-speed controller to controller traffic only (write cache mirroring).
Revision 1.3 Intel order number E15155-005
29
System Details
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
12 V bulk power is provided by the midplane. The Interposer has a power converter function for internal needs, and also supplies the disk drive power (12 V boost may be required). The VPD SEEPROM contains a WW (World Wide) unique address which the SCM uses to derive a SAS WWN (World Wide Name). It also contains manufacturing data, such as serial and version numbers for the Interposer. Hardware monitoring on the Interposer includes a temperature sensor. The data is passed back to the SCM via expander SES pages. Disk drive status LEDs are driven by expander GPIO signals, and collaboration logic must be present on the Interposer since either SCM (and either expander) can drive the status LEDs. 3.7.4.3 Drive Backplane Interface
The Interposer converts bulk 12 V from the midplane to provide +5 V and +12 V for disk drive power. Sufficient current is supplied for sequenced spin-up of drives in groups of 4-4-2-2-2 (for 2.5-inch configurations). Supported drive types include 15K RPM SAS drives. Signals are provided for single-color status LEDs for each disk drive. An expander sourced IC bus is connected to the drive backplane IDROM. Expanders send appropriate command/signal to an optional SATA active/active MUX dongle card on disk drive carriers to control 5 V and 12 V power.
3.8
Power Supply Module
The power supply module in Intel(R) Modular Server System MFSYS25/MFSYS35 is a 1000-W DC output supply with 110-240V AC input. Each power supply includes two fans that provide cooling for optional hot-swap disk drives. The power subsystem is configured as follows: With four power supply modules installed, a fully configured system has (3+1) power redundancy. With three power supply modules installed, a fully configured system would not have redundant power. Three power supply modules are capable of handling the maximum power requirements for fully configured platforms, which includes six compute modules, 192 GB of memory, two storage controllers, two Ethernet switch modules, one chassis management module, and fourteen hotswap 2.5-inch hard disk drives or six hot-swap 3.5-inch hard disk drives. When four power supply modules are installed, the user can replace a failed power supply module without affecting system functionality. Power supplies have two LEDs to identify failure, power good and AC OK. The power subsystem receives AC power through four power cords.
30 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
System Details
Note: The total power requirement for the platforms exceeds the 240 VA energy hazard limits that define an operator accessible area. As a result, only qualified technical individuals should access the processor and non-hot-plug I/O areas while the system is energized. Power cords should be removed from the system before accessing non-hot-plug areas.
3.9
Jumpers and LEDs
The compute module is the only module with jumper headers. Refer to the Intel(R) Compute Module MFS5000SI Technical Product Specification for details on the function and location of the server jumpers.
Revision 1.3 Intel order number E15155-005
31
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
4.
4.1
Product Regulatory Requirements
Product Regulatory Compliance
The Server Chassis product, when correctly integrated per this document, complies with the following safety, electromagnetic compatibility (EMC, and Product Ecology regulations and requirements. Intended Application - This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as: medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.), other than an ITE application, may require further evaluation.
4.1.1
Product Safety Compliance
UL60950 - CSA 60950(USA / Canada) EN60950 (Europe) IEC60950 (International) CB Certificate & Report, IEC60950 (report to include all country national deviations) GS Certification (Germany) GOST R 50377-92 - Certification (Russia) Belarus Certification (Belarus) Ukraine Certification (Ukraine) CE - Low Voltage Directive 73/23/EEE (Europe) IRAM Certification (Argentina) GB4943- CNCA Certification (China)
4.1.2
Product EMC Compliance - Class A Compliance
FCC /ICES-003 - Emissions (USA/Canada) Verification CISPR 22 - Emissions (International) EN55022 - Emissions (Europe) EN55024 - Immunity (Europe) EN61000-3-2 - Harmonics (Europe) EN61000-3-3 - Voltage Flicker (Europe) CE - EMC Directive 89/336/EEC (Europe) VCCI Emissions (Japan) AS/NZS 3548 Emissions (Australia / New Zealand) BSMI CNS13438 Emissions (Taiwan) GOST R 29216-91 Emissions (Russia) GOST R 50628-95 Immunity (Russia) Belarus Certification (Belarus) Ukraine Certification (Ukraine) KCC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea) GB 9254 - CNCA Certification (China) GB 17625 - (Harmonics) CNCA Certification (China)
32 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Regulatory Requirements
4.1.3
Product Ecology Compliance
Intel has a system in place to restrict the use of banned substances in accordance with world wide regulatory requirements. A Material Declaration Data Sheet is available for Intel products. For more reference on material restrictions and compliance you can view Intel's Environmental Product Content Specification at http://supplier.intel.com/ehs/environmental.htm. Europe - European Directive 2002/95/EC Restriction of Hazardous Substances (RoHS) Threshold limits and banned substances are noted below. Quantity limit of 0.1% by mass (1000 PPM) for: Lead, Mercury, Hexavalent Chromium, Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE) Quantity limit of 0.01% by mass (100 PPM) for: Cadmium California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials China - Restriction of Hazardous Substances (China RoHS) WEEE Directive (Europe) Packaging Directive (Europe)
4.1.4
Certifications / Registrations / Declarations
UL Certification (US/Canada) CE Declaration of Conformity (CENELEC Europe) FCC/ICES-003 Class A Attestation (USA/Canada) VCCI Certification (Japan) C-Tick Declaration of Conformity (Australia) MED Declaration of Conformity (New Zealand) BSMI Certification (Taiwan) GOST R Certification / License (Russia) Belarus Certification / License (Belarus) KCC Certification (Korea) IRAM Certification (Argentina) CNCA Certification (China) Ecology Declaration (International) China RoHS Environmental Friendly Use Period Packaging & Product Recycling Marks
4.2
Product Regulatory Compliance Markings
This Intel Server Chassis product is provided with the following regulatory and safety markings. In the event there is no room for a marking(s) on the chassis, the information is provided here in this document.
Revision 1.3 Intel order number E15155-005
33
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Requirement cULus Listing Marks
Country USA/Canada
Marking
GS Mark
Germany
CE Mark
Europe
FCC Marking (Class A)
USA
EMC Marking (Class A)
Canada
VCCI Marking (Class A)
Japan
34 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Regulatory Requirements
Requirement BSMI Certification & Class A Warning
Country Taiwan
Marking
GOST R Marking
Russia
KCC Mark
Korea
Note: The following is the former Korean EMC mark and is seen on older Intel products.
KCC Mark
Korea
Note: The following symbol is the new Korean EMC mark and is seen on newer Intel products.
China Compulsory Certification Mark
China
Management Methods on Control of Pollution from Electronic Information Products (China RoHS declaration)
.
(Parts)
.
Revision 1.3 Intel order number E15155-005
35
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Requirement
Country
Marking
(Metal Parts)
.
(Printed Board Assemblies (PBA))
'....SJ/T 11363-2006 ..
Indicates that this hazardous substance contained in all homogeneous materials of this part is below the limit requirement in SJ/T 11363-2006.
x'....SJ/T 11363-2006 . . x
Indicates that this hazardous substance contained in at least one of the homogeneous materials of this part is above the limit requirement in SJ/T 11363-2006.
.,'....'.. .''
This table shows where these substances may be found in the supply chain of our electronic information products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or may not be a part of the enclosed product.
36 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Regulatory Requirements
Requirement Belarus Safety Compliance Mark
Country Belarus
Marking
Waste of Electronic and Electrical Equipment Recycling Mark
Europe
China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China Recycling Mark
China
China
Recycling Marks
International
Battery Perchlorate Warning Information
California
Perchlorate Material - Special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, and Chapter 33: Best Management Practices for Perchlorate Materials. This product may include a battery which contains Perchlorate material.
Revision 1.3 Intel order number E15155-005
37
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Requirement Safety
Country Multiple Power Cord Marking
Marking
This unit has more than one power supply cord. To reduce the risk of electrical shock, disconnect (2) two power supply cords before servicing. Simplified Chinese:
Traditional Chinese:
German: Dieses GerSte hat mehr als ein Stromkabel. Um eine Gefahr des elektrischen Schlages zu verringern trennen sie beide (2) Stromkabeln bevor Instandhaltung.
Nordic Countries
Connection to Proper Ground Outlet
"WARNING:" "Apparaten skall anslutas till jordat uttag, nSr den ansluts till ett nStverk." "Laite on liitettSva suojamaadoituskoskettimilla varustettuun pistorasiaan." "Connect only to a properly earth grounded outlet."
Safety
Standyby power
4.3
Regulated Specified Components
To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other component will void the UL listing and other product certifications and approvals. You can find updated product information for configurations on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder If you do not have access to Intel's Web address, contact your local Intel representative. 1. Server Chassis: Base chassis is provided with power supply and fans--UL listed. 2. Server board: You must use an Intel server board--UL recognized.
38 Intel order number E15155-005 Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Regulatory Requirements
3. Add-in Boards: Must have a printed wiring board flammability rating of minimum UL94V-1. Add-in boards containing external power connectors and/or lithium batteries must be UL recognized or UL listed. Any add-in board containing modem telecommunication circuitry must be UL listed. In addition, the modem must have the appropriate telecommunications, safety, and EMC approvals for the region in which it is sold. 4. Peripheral Storage Devices: Must be UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply.
4.4
4.4.1
Electromagnetic Compatibility Notices
FCC Verification Statement (USA)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 Phone: 1-800-628-8686 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and the receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product. Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC Class A or B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception. All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals that are not shielded and grounded may result in interference to radio and TV reception.
Revision 1.3 Intel order number E15155-005
39
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
4.4.2
ICES-003 (Canada)
Cet appareil numZrique respecte les limites bruits radioZlectriques applicables aux appareils numZriques de Classe A prescrites dans la norme sur le matZriel brouilleur: "Appareils NumZriques", NMB-003 ZdictZe par le Ministre Canadian des Communications. English translation of the notice above: This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled "Digital Apparatus," ICES-003 of the Canadian Department of Communications. Recycle battery in accordance with applicable WEEE and Battery laws.
Perchlorate Material - special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material.
4.4.3
Europe (CE Declaration of Conformity)
This product has been tested in accordance too, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance. Recycle battery in accordance with applicable WEEE and Battery laws.
Perchlorate Material - special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material.
40 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Product Regulatory Requirements
4.4.4
VCCI (Japan)
English translation of the notice above: This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Recycle battery in accordance with applicable WEEE and Battery laws.
Perchlorate Material - special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material.
4.4.5
BSMI (Taiwan)
The BSMI Certification Marking and EMC warning is located on the outside rear area of the product.
Recycle battery in accordance with applicable WEEE and Battery laws.
Revision 1.3 Intel order number E15155-005
41
Product Regulatory Requirements
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Perchlorate Material - special handling may apply. See: http://www.dtsc.ca.gov/hazardouswaste/perchlorate This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product/part includes a battery which contains perchlorate material.
42 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Glossary
Glossary
This appendix contains important terms used in the preceding sections. Acronyms are followed by non-acronyms.
Word / Acronym ACPI BIOS BMC CE CISPR CMM CMOS CSA DB dBA DDR2 DIMM DMA ECC EEPROM EMC EMI EMP EPS ESD ESM FCC FPGA FRB FRU FSB FWH GbE GND GUI HDD HL HSC I/O IC ICMB IDE IEC Definition Advanced Configuration and Power Interface Basic Input / Output System Baseboard Management Controller European Conformity (Conformite Europeenne) Special International Committee on Radio Interference (Comite International Special des Perturbations Radioelectriques) Chassis Management Module Complementary Metal-Oxide Semiconductor Canadian Standards Organization Data Bus Decibel Acoustic Double Data Rate Dual In-line Memory Module Direct Memory Access Error Checking Code Electrically Erasable Programmable Read-Only Memory Electromagnetic Compatibility Electromagnetic Interference Emergency Management Port External Product Specification Electrostatic Discharge Ethernet Switch Module Federal Communications Commission Field-Programmable Gate Array Fault Resilient Booting Field Replaceable Unit Front Side Bus Firmware Hub Gigabit Ethernet Ground Graphical User Interface Hard Disk Drive Hub-Link Hot-Swap Controller Input / Output Inter-Integrated Circuit Intelligent Chassis Management Bus Integrated Device Electronics International Electrotechnical Commission
Revision 1.3 Intel order number E15155-005
43
Glossary
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Word / Acronym IMB IPMB IPMI ISP ITE ITP JTAG KVM LAN LED LPC LVDS NIC OEM OS OTP PCI PDB PEF PEP PFC PIROM PLD PSM PSU PWM RAID RAS RASUM ROMB RPM RoHS SAF-TE SAS SATA SCA SCL SCM SCSI SDA SDINT SDR SDRAM SE
Definition Intelligent Management Bus Intelligent Platform Management Bus Intelligent Platform Management Interface In-System Programmable Information Technology Equipment In-Target Probe Joint Test Action Group Keyboard, VDU, and Mouse Local Area Network Light Emitting Diode Low-Pin Count Low Voltage Differential SCSI Network Interface Card Original Equipment Manufacturer Operating System Over-Temperature Protection Peripheral Component Interconnect Power Distribution Board Platform Event Filtering Platform Event Paging Power Factor Correction Processor Information Read-Only Memory Programmable Logic Device Power Supply Module Power Supply Unit Pulse Width Modulator Redundant Array of Independent Disks Reliability, Availability, and Serviceability Reliability, Availability, Serviceability, Usability, and Manageability RAID On Motherboard Revolutions Per Minute Restriction of Hazardous Substances SCSI Accessed Fault-Tolerant Enclosure Serial Attached SCSI Serial Advanced Technology Attachment Single Connector Attachment Serial Clock Switch Controller Module Small Computer Systems Interface Serial Data System Diagnostic Interrupt Sensor Data Record Synchronous Dynamic Random Access Memory Single-Ended
44 Intel order number E15155-005
Revision 1.3
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Glossary
Word / Acronym SEEPROM SEL SerDes SMASH CLP SMP SNMP SOL TTL TUV USB UL UV VAC VCC VCCI VDE VDU VGA VID VRM VSB WfM WS WS-MAN XAUI
Definition Serial Electrically Erasable Programmable Read-Only Memory System Event Log Serializer/Deserializer Systems Management Architecture for Server Hardware/Command Line Protocol Symmetric Multiprocessing Simple Network Management Protocol Serial Over LAN Transistor-Transistor Logic Technical Monitoring Association (Technischer Uberwachungsverein) Universal Serial Bus Underwriters Laboratories, Inc. Under-Voltage Alternating Current (AC) voltage Voltage Controlled Current Voluntary Control Council for Interference by Information Technology Equipment Association for Electrical, Electronic and Information Technologies (Verband der Elektrotechnik, Elektronik und Informationstechnik) Video Display Unit Video Graphics Array Voltage Identifier Voltage Regulator Module Voltage Standby Wired for Management Web Services WS-Management 10-Gigabit Attachment Unit Interface
Revision 1.3 Intel order number E15155-005
45
Reference Documents
Intel(R) Modular Server System MFSYS25/MFSYS35 TPS
Reference Documents
See the following documents for additional information: SCSI Accessed Fault-Tolerant Enclosures Interface Specification (SAF-TE) Intel(R) Compute Module MFS5000SI Technical Product Specification (TPS) Intel(R) Modular Server System MFSYS25/MFSYS35 Tested Hardware and Operating Systems List (THOL) IPMI Specification, Version 2.0
46 Intel order number E15155-005
Revision 1.3


▲Up To Search▲   

 
Price & Availability of MFSYS25

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X