Part Number Hot Search : 
AP9T15GH 4HC405 DTA123E 64000 20N03 PDTC114T 80020 1F006
Product Description
Full Text Search
 

To Download PSU50A-13 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 44~49W AC-DC Dual Output Desktop
Features :
3 pole AC inlet IEC320-C14 Class power (with earth pin)
P50A-D
series
Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Fix switching frequency and regulation Topology: PWM 3882 circuit LED indicator for power on Approvals: UL / CUL / TUV / CB / CE 1 year warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE P50A13-R1B PSU50A-13
Note.2 5V
TUV Rheinland Product Safety
geprUfre Sicherheit
P50A14-R1B PSU50A-14 12V 2A 0.1 ~ 2.0A 100mVp-p 10% 1.0% 9.0% 135 ~ 370VDC 74% 5V 4A 0.5 ~ 4.0A 47W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 9.0% 15V 1.8A 0.1 ~1.8A
P50A16-R1B PSU50A-16 5V 4A 0.5 ~ 4.0A 49W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 9.0% 24V 1A 0.1 ~ 1.0A
4A 0.5 ~ 4.0A 44W
RIPPLE & NOISE (max.) Note.3 50mVp-p Fixed VOLTAGE TOLERANCE Note.4 6.0% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT(max.) OVERLOAD
Note.5 Note.6
1.0% 5.0% 90 ~ 264VAC 47 ~ 63Hz 70% 1.6A / 100VAC 40A / 230VAC 0.75mA / 240VAC
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load
INPUT
75%
150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 110 ~ 140% of rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 0 ~ +40 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1950, CSA22.2, EN60950-1 approved
PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note. 7)
I/P-O/P:3KVAC , I/P-FG:1.5KVAC I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022(CISPR22) class B HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A 280K hrs min. MIL-HDBK-217F (25 ) 147*76*43mm (L*W*H) 0.55kg; 36pcs / 21kg / CARTON Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
DIMENSION PACKING PLUG CONNECTOR CABLE NOTE
OTHERS
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerence: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:P50A-D-SPEC 2007-05-14
44~49W AC-DC Dual Output Desktop
Mechanical Specification
P50A-D
series
Unit:mm
UL2464 18AWG 1220+100/-0
43
43
144.5
54.8 10.2
SWITCHING ADAPTOR
76
POWER LED 147
Plug Assignment
144.5 69.9 21.5
Standard plug: R1B (option)
PIN NO OUTPUT COM COM +5VDC - Vout +Vout
38
1
524 3 1 45
o
40
42
76
2 3 4 5
NAME PLATE
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
100
LOAD (%)
LOAD (%)
80 60
60
0
10
20
30
40
0
50
60
70
80
90 100
260
Ta (
)
INPUT VOLTAGE
File Name:P50A-D-SPEC 2007-05-14
46.5~50W AC-DC Triple Output Desktop
Features :
3 pole AC inlet IEC320-C14
P50A-T
series
Class power (with earth pin) Protections: Short circuit / Overload / Over voltage Fully enclosed plastic case Fix switching frequency and regulation Topology: PWM 3882 circuit LED indicator for power on Approvals: UL / CUL / TUV / CB / CE 1 year warranty
SPECIFICATION
ORDER NO. SAFETY MODEL NO. DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE P50A13A-R1B PSU50A-13A
Note.2 5V
TUV Rheinland Product Safety
geprUfre Sicherheit
P50A13D-R1B PSU50A-13D -5V 0.5A 0.1 ~ 0.5A 100mVp-p 12% 1.0% 10% 5V 4A 0.5 ~ 4.0A 50W 50mVp-p 6.0% 1.0% 5.0% 12V 2A 0.5 ~2.0A 100mVp-p 10% 1.0% 10% -12V 0.5A 0.1 ~0.5A 100mVp-p 12% 1.0% 10%
P50A14E-R1B PSU50A-14E 5V 4A 0.5 ~ 4.0A 50W 50mVp-p 6.0% 1.0% 5.0% 100mVp-p 10% 1.0% 10% 100mVp-p 12% 1.0% 10% 15V 1.5A 0.5 ~ 1.5A -15V 0.5A 0.1 ~ 0.5A
12V 2A 0.5 ~ 2.0A 100mVp-p 10% 1.0% 10%
4A 0.5 ~ 4.0A 46.5W
RIPPLE & NOISE (max.) Note.3 50mVp-p Fixed VOLTAGE TOLERANCE Note.4 6.0% LINE REGULATION LOAD REGULATION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD
Note.5 Note.6
1.0% 5.0% 90 ~ 264VAC 47 ~ 63Hz 70% 1.6A / 100VAC 40A / 230VAC
SETUP, RISE, HOLD UP TIME 1.5s, 50ms, 12ms at full load 135~ 370VAC 72% 74%
INPUT
0.75mA / 240VAC 150 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5V: 110 ~ 140% of rated output voltage Protection type : Shut down o/p voltage, re-power on to recover 0 ~ +40 (Refer to output load derating curve) 20% ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03% / (0 ~ 50 ) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL1950, CSA22.2, EN60950-1 approved I/P-O/P:3KVAC , I/P-FG:1.5KVAC I/P-O/P,I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55022(CISPR22) class B Compliance to EN61000-3-2,3 Compliance to EN61000-4-2,3,4,5,6,11, ENV50204, light industry level, criteria A 280K hrs min. MIL-HDBK-217F (25 ) 147*76*43mm (L*W*H) 0.55kg; 36pcs / 21kg / CARTON Standard type R1B: DIN 5PIN for stock ; Other type available by customer requested Standard type AWM2464 18Awg*4c with shiell 4ft for stock ; Other type available by customer requested
PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note. 7) HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING PLUG CABLE
CONNECTOR NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerence: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 20% to 100% rated load. 7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
File Name:P50A-T-SPEC 2007-05-14
46.5~50W AC-DC Triple Output Desktop
Mechanical Specification
P 5500A --T s erriieess P A T se
Unit:mm
UL2464 18AWG 1220+100/-0
43
43
144.5
54.8 10.2
SWITCHING ADAPTOR
76
POWER LED 147
Plug Assignment
144.5 69.9 21.5
Standard plug: R1B (option)
PIN NO OUTPUT COM COM +5VDC - Vout +Vout
38
1
524 3 1 45
o
40
42
76
2 3 4 5
NAME PLATE
RUBBER FOOTX4
Derating Curve
Static Characteristics
100
100
LOAD (%)
LOAD (%)
0 10 20 30 40
80 60
60
0
50
60
70
80
90 100
260
Ta (
)
INPUT VOLTAGE
File Name:P50A-T-SPEC 2007-05-14


▲Up To Search▲   

 
Price & Availability of PSU50A-13

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X