|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS230.doc version 2.0 08.03.2000 VI TELEFILTER Measurement Condition Ambient Temperature: Input Power Level: Source impedance: Load impedance: Terminating impedances: input: output: 23 C 0 dBm 50 50 Filter specification TFS 230 1/5 2,0 k || -4,7 pF 1,4 k || -4.9 pF Characteristics Remark: Reference level for the relative attenuation arel is the minimum pass band attenuation amin. It is defined as the insertion loss ae. The nominal frequency fN is fixed to 230,0 MHz. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1,2 dB filter attenuation level relative to the insertion loss ae. The given values for the insertion loss, the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion Loss (Reference level) Nominal Frequency 1.2 dB - Bandwidth Pass Band Ripple fN 1,950 MHz Relative Attenuation arel ae = amin typ. Value 13,0 dB max. Limit 14,5 dB fN BW 4,2 dB min. 230,0 MHz 3,9 MHz 0,7 dB max. 1,2 dB fN 3,0 MHz ... fN 5,0 MHz 30 dB min. 18 dB fN 5,0 MHz ... fN 10,0 MHz 47 dB min. 45 dB fN 10,0 MHz ... fN 100,0 MHz 57 dB min. 50 dB ______________________________________________________________________________________________________ Group delay ripple fN 1,950 MHz 100 ns max. 150 ns VSWR fN 1,950 MHz Operating Temperature Range 1,8:1 max. 2:1 - 30 C ... + 80 C Generated: Checked / approved: VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS230.doc version 2.0 08.03.2000 VI TELEFILTER Construction and pin connection Filter specification TFS 230 2/5 TFS 230 N10 Datecode - 1 2 3 4 5 6 7 8 9 10 Ground Ground Ground Output RF Return Output Ground Ground Ground Input RF- Return Input R0.15 Datecode: L M N ... Year+week 1999 2000 2001 50 test circuit Input L1 10 L3 5 Output L2 9 SAW 4 L4 1,2,3,6,7,8 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS230.doc version 2.0 08.03.2000 VI TELEFILTER Stability Characteristics Filter specification TFS 230 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 7,5 0,1 0,6 2 0,1 8 0,1 1,5 5,6 11,8 21,5 0,1 0,1 0,1 COVER TAPE EMBOSSED CARRIER TAPE Do Po P2 E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo CT : : E Ao F W D1 CT Bo G P1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,4 +2 30,4 60 C A N 13 +0,5/-0,2 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS230.doc version 2.0 08.03.2000 VI TELEFILTER Air reflow temperature conditions Filter specification TFS 230 4/5 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS230.doc version 2.0 08.03.2000 VI TELEFILTER History Version 1.2 Reason of Changes - modified package Filter specification TFS 230 5/5 Name Steiner Date 07.04.2000 1.3 loss changed from 17dB to 14,5 dB package changed from 13x6mm to 11x5mm extended specification - tape and reel information added - airflow profile information added - terminating impedances added - loss definition corrected Steiner 23.05.2000 2.0 Steiner 08.03.2001 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS230 | |
|
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |