    A77-727-01

Systemsensor advanced ideas.
Part No. A77-727-01
OCR Text ...PA72 required audible emergency evacuation signal referred to as temporal (3) tone. An external push button provides a test of the detector's alarm function. Up to 12 units can be interconnected so that if one detector alarms, all detectors...
Description Direct-Wire Smoke Detector with Built-in Relay and Horn

File Size 151.42K  /  2 Page

View it Online

Download Datasheet





    SP2R1224MCK

Systemsensor advanced ideas.
Part No. SP2R1224MCK
OCR Text ...e and intelligible broadcast of evacuation messages. High sound *Wide range of candela options: pressure level at all tap settings ensures that messages are clearly 12V: 15 and 15/75 candela options heard. 24V: 15, 15/75, 30, 75, and 110 ca...
Description Selectable Output Outdoor Wall Speaker/Strobes

File Size 134.36K  /  2 Page

View it Online

Download Datasheet

    SP2R1224MC SP3W1224MC

Systemsensor advanced ideas.
Part No. SP2R1224MC SP3W1224MC
OCR Text ...e and intelligible broadcast of evacuation messages. Installation. SpectrAlert Selectable Output Speaker/Strobes offer a variety of installation-friendly features, such as the ability to mount to a 4 x 4 x 218 back box without the need for ...
Description Selectable Output Wall Speaker/Strobes

File Size 234.63K  /  2 Page

View it Online

Download Datasheet

    SP2R24110 SP2R2415 SP2R241575 SP2R2430 SP2R2475 SP2W24110 SP2W2415 SP2W241575 SP2W2430

Systemsensor advanced ideas.
Part No. SP2R24110 SP2R2415 SP2R241575 SP2R2430 SP2R2475 SP2W24110 SP2W2415 SP2W241575 SP2W2430
OCR Text ...of the SpectrAlert SP200 series evacuation speaker. Installation. The SpectrAlert SP2 series includes several features to simplify installation. With a field-reversible strobe, the SP2 wall speaker/strobes may be either leftor right-mounted...
Description Wall Speaker Strobes

File Size 165.72K  /  2 Page

View it Online

Download Datasheet

    AOM-MUXF

Gamewell-FCI by Honeywell
Part No. AOM-MUXF
OCR Text evacuation Modules AOM-MUXF The Gamewell-FCI Velociti(R) Series, multiplex output module (AOM-MUXF) is used in dual-channel bulk audio systems to select the alarm tone and/or recorded voice message to be transmitted to each evacuation z...
Description Telephone monitor module

File Size 393.96K  /  1 Page

View it Online

Download Datasheet

    AS7405 AH7415 AH7416 AS7410 ASW9012 AS9024 AH7891 AH7892

Gamewell-FCI by Honeywe...
Gamewell-FCI by Honeywell
Part No. AS7405 AH7415 AH7416 AS7410 ASW9012 AS9024 AH7891 AH7892
OCR Text ...rn mandated by NFPA 72 for fire evacuation signaling. This ensures a clearly distinguishable temporal pattern when two or more audible devices are within hearing distance. If the horn tones are not synchronized, the temporal patterns may ov...
Description Cooper-Wheelock AS/AH Serles

File Size 231.93K  /  4 Page

View it Online

Download Datasheet

    CAB-C CAB-A

Gamewell-FCI by Honeywell
Part No. CAB-C CAB-A
OCR Text ...0 Distributed Fire Alarm/ Voice evacuation System Operation 80-Character Alpha-numeric Display Listed Integral Sensitivity Testing meets NFPA 72 Testing Requirements Drift Compensation Overcomes Effects of Aging or Environment on Sensor Sen...
Description MULTIPROCESSOR-BASED

File Size 166.40K  /  4 Page

View it Online

Download Datasheet

    DS2475RAR

Systemsensor advanced i...
Systemsensor advanced ideas.
Part No. DS2475RAR
OCR Text ...larms, security, tornado alert, evacuation, etc. Performance. Based upon the principles of the original SpectrAlert wall mount strobes, the Dual Strobe models operate at 24 volts, and provide 75 candela output per UL 1638. The strobes m...
Description    SpectrAlert Dual Strobe Notification Appliances

File Size 266.64K  /  2 Page

View it Online

Download Datasheet

    SSM610-2 SSM610-4

Gamewell-FCI by Honeywell
Part No. SSM610-2 SSM610-4
OCR Text ...ay. * Optional integrated voice evacuation. * Optional UDACT. * Agent Releasing service. An ISO 9000-2000 Company SIGNALING Operator's Display The IF610SS's operator's display provides all user access to the system. The display has al...
Description Analog Addressable Control Panel

File Size 75.42K  /  3 Page

View it Online

Download Datasheet

    AM-50

Gamewell-FCI by Honeywell
Part No. AM-50
OCR Text ...3 SeriesTM Expandable Emergency evacuation System and E3 SeriesTM Broadband Audio evacuation System. The INX transponder serves as the point of distribution for the system's audio and fire fighter telephone risers. The INX occupies a single...
Description Transponder Voice Gateway

File Size 231.17K  /  4 Page

View it Online

Download Datasheet

For evacuation Found Datasheets File :: 142    Search Time::1.187ms    
Page :: | 1 | 2 | 3 | <4> | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |   

▲Up To Search▲

 




Price and Availability




 
Price & Availability of evacuation

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X
1.1407730579376